AC/DC Digital Clamp Meter |
|
|
|
|
|
|
|
| Frequency
Characteristic |
ACA
: 40Hz to 400Hz ACV
: 40Hz to 400Hz |
| Safety
Standards |
IEC-61010-1 (CAT III 300V CAT II
600V, EMC Test Passed) |
| Power
Supply |
1.5V R03 or AAA Batteries ~
2 |
| Dimensions
& Weight |
170(H) ~ 58(W)
~ 27(D)mm, 160g |
| Conductor
Diameter |
ƒ³
27mm maximum |
| Accessories |
100-63 Test
Lead (x 1), 1015 Carrying Case, Batteries (1.5V R03 x
2),
Instruction Manual
|
| Optional
Accessories |
940 Alligator
Clips
|
793 Coil-Type Contact Pin
|
|
948 Alligator
Clips
|
@
|
|
|
|
|
Measurement Specifications
|
Average Rectification
|
| @ |
Range |
Accuracy |
DCA/ACA
Hz |
DC
Current |
40A |
}1.5%rdg}3dgt |
| 400A |
40 to
200A / }1.5%rdg}5dgt
201 to 300A / }3.0%rdg}3dgt
301 to 400A / }4.0%rdg}3dgt |
| AC
Current |
40A |
}1.5%rdg}2dgt (50/60Hz) |
| 400A |
40
to 200A / }2.0%rdg}3dgt 50/60Hz)
201 to 300A /
}4.0%rdg}5dgt 50/60Hz)
301 to 400A /
}5.0%rdg}5dgt 50/60Hz) |
| Frequency |
5Hz
to 1kHz |
}0.2%rdg}2dgt |
DCV/ACV
Hz/% |
DC
Voltage |
400mV |
}1.0%rdg}3dgt |
| 4/40/400/600V |
}1.0%rdg}2dgt |
| AC
Voltage |
4/40/400/600V |
}1.5%rdg}5dgt
(40 to 400Hz) |
| Frequency |
5Hz
to 49.99kHz |
}0.2%rdg}2dgt |
| Duty
Cycle |
5%
to 95% |
}1.0%rdg}3dgt |
| Resistance |
400Ħ
|
}1.5%rdg}5dgt |
| 4k/40k/400kĦ
|
}0.7%rdg}3dgt |
| 4MĦ
|
}1.2%rdg}5dgt |
| 40MĦ
|
}3.0%rdg}5dgt |
|
Other Functions |
Continuity,
Diode Test, Capacitance, MAX/MIN, Difference,
Power-on Initialize, Display Hold, Auto Power Off
|
|
|
|