| Safety
Standards |
IEC-61010-1 (CAT III 600V, EMC
Test Passed)
|
| Power
Supply |
1.5V R6P or AA Batteries x 6
|
| Fuse |
F23 (1A/600V / 6.3Φ× 32mm) x 1 |
Dimensions
& Weight |
169(H)×148(W)×50(D)mm, 570g |
| Accessories |
100-40-2 Test Lead (x 1), 942 Black
Alligator Clip (x 1),
766 Red Test Prod (x 1, with 767 Test Pin), Batteries (1.5V R6P x 6),
Spare Fuse (x 1), Instruction Manual
|
| Optional
Accessories |
766 Black
Test Prod (with 767 Test Pin)
942 Red Alligator Clip
|
|
|
|
|
Measurement Specifications
|
| Rated
Voltage |
250V |
500V |
1000V |
Insulation
Resistance |
Resistance |
50MΩ |
100MΩ |
2000MΩ |
Measurement
Range |
0.01
to 50MΩ |
0.05 to 100MΩ |
1 to 2000MΩ |
Center
Scale |
1MΩ |
2MΩ |
50MΩ |
Allowable
Voltage
without
Loading |
1.3
times or less of rated voltage |
Measuring
Current |
1mA
to 1.2mA |
Shorted
Current |
2mA
or less |
| AC
Voltage |
0
to 600V |
| Accuracy |
Insulation
Resistance |
First
effective range : ±5% of reading value
Second effective range : ±10% of reading value
The other scale area : ±0.7% of scale length |
| AC
Voltage |
±3%
of full scale value |
| Other
Functions |
Live Wire Warning, Capacitance
Discharge,
Timer Function (Approx. 3 minutes
continuous measurement),
Battery Check (confirmable on meter scale) |
|
|
|